What is the DS3231?
The DS3231 is the real-time clock to use when your project needs to know the actual time: a data logger that timestamps readings, a clock or alarm, a timer that switches a relay at 7:00, or an ESP32 that must keep time without Wi-Fi. It keeps counting while your microcontroller is off, thanks to a coin cell on the back, and it is far more accurate than the older DS1307.
The difference is the crystal. The DS3231 has a temperature-compensated crystal oscillator (TCXO) built into the chip: it measures its own temperature every 64 seconds and corrects the crystal's frequency. That keeps it within ±2 ppm, about a minute per year, where a plain 32 kHz crystal drifts several times faster and changes with the room temperature. This page covers the pins, the I2C addresses, the charging circuit that catches out most buyers, and how to use the alarms.
Specifications
- Accuracy
- ±2 ppm from 0 to 40 °C (about ±1 minute per year)
- Interface
- I2C, up to 400 kHz
- I2C address
- 0x68 (DS3231), 0x57 (AT24C32 EEPROM on the module)
- Supply voltage
- 2.3–5.5 V, so it works with 3.3 V and 5 V boards
- Current
- about 200 µA active; a few µA on the backup cell
- Backup battery
- CR2032 coin cell (LIR2032 if the charging circuit is kept)
- Timekeeping
- Seconds to year, leap years corrected until 2100
- Alarms
- Two programmable alarms, output on the SQW/INT pin
- Square wave
- 1 Hz, 1.024 kHz, 4.096 kHz or 8.192 kHz on SQW, 32.768 kHz on 32K
- Temperature sensor
- ±3 °C accuracy, 0.25 °C resolution
- EEPROM (module)
- AT24C32, 4 KB, for storing settings or logs
Figures from the Maxim/Analog Devices DS3231 datasheet. The common ZS-042 module adds the EEPROM, pull-ups and the battery holder.
DS3231 module pinout
| Pin | Function | Notes |
|---|---|---|
| 32K | 32.768 kHz output | Open-drain clock output; leave unconnected unless you need it |
| SQW | Square wave or alarm | Open-drain, active LOW for alarms: use a pull-up (INPUT_PULLUP) |
| SCL | I2C clock | Uno A5, ESP32 GPIO22 |
| SDA | I2C data | Uno A4, ESP32 GPIO21 |
| VCC | Supply | 3.3 V or 5 V |
| GND | Ground | Common with the microcontroller |
Wiring & code
Setting up DS3231 with Arduino Uno
Library
RTClib by Adafruit
Arduino IDE → Library Manager: search "RTClib" and install RTClib by Adafruit (it installs Adafruit BusIO too).
This guide connects a DS3231 RTC module to an Arduino Uno, sets the clock from your computer, prints the date, time and temperature every second, and then uses the DS3231's alarm to trigger an interrupt. Read the DS3231 overview first if you use a CR2032 cell: the module's charging resistor should come off.
Wiring: DS3231 to Arduino Uno
| DS3231 pin | Uno pin | Note |
|---|---|---|
| VCC | 5V | 3.3 V also works |
| GND | GND | Common ground |
| SDA | A4 | I2C data (also the SDA pin near AREF on R3 boards) |
| SCL | A5 | I2C clock |
| SQW | D2 | Only for the alarm example; uses INPUT_PULLUP |
- 1Fit the CR2032 in the holder, flat (+) side up.
- 2Connect VCC, GND, SDA and SCL as in the table.
- 3Install RTClib by Adafruit from the Library Manager.
- 4Upload the first sketch and open the Serial Monitor at 9600 baud.
Sketch 1: set the clock and print the time
The first time it runs (or whenever the backup cell has been removed), rtc.lostPower() is true and the sketch sets the clock to the moment the sketch was compiled. After that it leaves the time alone, so re-uploading or resetting the Uno does not change it.
#include <RTClib.h>
RTC_DS3231 rtc;
const char* DAYS[] = {"Sun", "Mon", "Tue", "Wed", "Thu", "Fri", "Sat"};
void setup() {
Serial.begin(9600);
if (!rtc.begin()) {
Serial.println("Couldn't find the DS3231 - check SDA (A4) and SCL (A5)");
while (true) {}
}
if (rtc.lostPower()) {
Serial.println("RTC lost power, setting it to the compile time");
rtc.adjust(DateTime(F(__DATE__), F(__TIME__)));
}
rtc.disable32K(); // the 32K output isn't used here
}
void loop() {
DateTime now = rtc.now();
char buf[32];
snprintf(buf, sizeof(buf), "%s %04d-%02d-%02d %02d:%02d:%02d",
DAYS[now.dayOfTheWeek()], now.year(), now.month(), now.day(),
now.hour(), now.minute(), now.second());
Serial.print(buf);
Serial.print(" ");
Serial.print(rtc.getTemperature(), 2);
Serial.println(" C");
delay(1000);
}The compile time is a few seconds behind the real time by the time the upload finishes. For an exact setting, use rtc.adjust(DateTime(2026, 11, 26, 14, 30, 0)) once with the correct values, then remove that line and upload again.
Sketch 2: an alarm on an interrupt
Connect SQW to D2. The sketch sets Alarm 1 to fire whenever the seconds match: ten seconds from now, then once a minute at that second. The DS3231 pulls SQW LOW, the interrupt sets a flag, and the loop prints the time and clears the alarm so it can fire again. Replace the print with whatever should happen on schedule, such as switching a relay or taking a reading.
#include <RTClib.h>
RTC_DS3231 rtc;
const byte ALARM_PIN = 2; // SQW -> D2
volatile bool alarmFlag = false;
void onAlarm() { alarmFlag = true; }
void setup() {
Serial.begin(9600);
if (!rtc.begin()) { Serial.println("No RTC"); while (true) {} }
if (rtc.lostPower()) rtc.adjust(DateTime(F(__DATE__), F(__TIME__)));
rtc.disable32K();
rtc.clearAlarm(1);
rtc.clearAlarm(2);
rtc.writeSqwPinMode(DS3231_OFF); // SQW acts as the alarm output
rtc.disableAlarm(2);
pinMode(ALARM_PIN, INPUT_PULLUP); // SQW is open-drain
attachInterrupt(digitalPinToInterrupt(ALARM_PIN), onAlarm, FALLING);
// Fire when the seconds match: 10 s from now, then once a minute
rtc.setAlarm1(rtc.now() + TimeSpan(10), DS3231_A1_Second);
Serial.println("Alarm set - waiting...");
}
void loop() {
if (alarmFlag) {
alarmFlag = false;
DateTime t = rtc.now();
Serial.print("Alarm at ");
Serial.println(t.timestamp(DateTime::TIMESTAMP_TIME));
rtc.clearAlarm(1); // releases SQW so it can fire again
}
}To trigger at a fixed time instead, use DS3231_A1_Hour with a DateTime holding the hour, minute and second you want: rtc.setAlarm1(DateTime(2026, 1, 1, 7, 0, 0), DS3231_A1_Hour) fires every day at 07:00:00.
Troubleshooting
Couldn't find the DS3231
- Likely cause
- SDA/SCL swapped or loose
- Fix
- SDA to A4, SCL to A5; run an I2C scanner, expect 0x68
Time jumps back after a reset
- Likely cause
- rtc.adjust() runs every time
- Fix
- Keep it inside if (rtc.lostPower())
Shows 2000-01-01 after unplugging
- Likely cause
- Backup cell flat or missing
- Fix
- Fit a fresh CR2032
Alarm fires once only
- Likely cause
- Alarm flag not cleared
- Fix
- Call rtc.clearAlarm(1) after each alarm
Alarm never fires
- Likely cause
- SQW not on D2, or no pull-up
- Fix
- Check the wire; keep INPUT_PULLUP
Where to go next
- Show the time on an LCD 1602 I2C or a TM1637 display: both share the I2C or use two spare pins.
- Log sensor readings with timestamps: the module's AT24C32 EEPROM (address 0x57) holds a few hundred readings.