Capacitor Calculator
Calculate capacitive reactance (Xc) at a given frequency, the energy stored in a capacitor, and the charge/discharge time constants. Covers decoupling, filter, and energy storage applications.
Capacitor Math
Capacitors store electrical charge and energy. Calculate capacitance from charge and voltage, find capacitive reactance (AC opposition) at a given frequency, or determine the energy stored. Essential for filter design, timing circuits, and power factor correction.
Select a calculation mode and enter values
1 mC = 0.001 C
Enter the required values to calculate.
What this calculator works out
- Capacitive reactance: Xc = 1 ÷ (2π f C). It is the capacitor's "AC resistance": high at low frequencies, low at high frequencies. That is why a capacitor blocks DC but passes audio or switching noise.
- Stored energy: E = ½ C V². A 1000 µF capacitor charged to 25 V holds 0.31 J, enough to give a noticeable spark when shorted.
- Charge time: through a resistor, a capacitor reaches 63 % of the supply after one time constant τ = R × C and is considered fully charged after about 5τ.
Reading ceramic capacitor codes
Small capacitors print a three-digit code in picofarads: two digits followed by a number of zeros.
| Code | Value | Common use |
|---|---|---|
| 101 | 100 pF | RF and timing |
| 102 | 1 nF | Filtering |
| 103 | 10 nF | Debouncing, snubbers |
| 104 | 100 nF (0.1 µF) | Decoupling next to every IC |
| 105 | 1 µF | Regulator stability |
| 106 | 10 µF | Bulk decoupling (MLCC) |
A letter after the code is the tolerance: J = ±5 %, K = ±10 %, M = ±20 %. Electrolytic capacitors print the value and voltage directly (for example 470 µF 16 V).
Unit conversions
1 F = 1 000 000 µF · 1 µF = 1000 nF · 1 nF = 1000 pF. So 0.1 µF = 100 nF = 100 000 pF.
Choosing a voltage rating
Pick a rating at least 1.5–2× the highest voltage the capacitor will see. Ceramic (X5R/X7R) capacitors also lose much of their capacitance as DC voltage rises: a 10 µF 6.3 V MLCC may only give 4 µF at 5 V. Electrolytics are polarised, so the stripe marks the negative lead, and reversing them can make them vent.
Decoupling in microcontroller projects
Place a 100 nF ceramic capacitor as close as possible to each IC's power pins, and add a 10–100 µF electrolytic or MLCC where power enters the board. An ESP32 drawing Wi-Fi current bursts of several hundred milliamps commonly needs 100–470 µF near its 3.3 V regulator to avoid brownout resets.
Formula, inputs and worked examples
Formula and method
Xc = 1/(2πfC); stored energy E = ½CV²; first-order RC time constant τ = RC.
Worked examples
Reactance of a decoupling capacitor
A 100 nF capacitor has Xc = 1 / (2π × 1,000,000 × 0.0000001) = 1.59 Ω at 1 MHz, which makes it a good short for fast noise. At 50 Hz the same capacitor is 31.8 kΩ, so it barely passes mains-frequency signals.
Energy in a 1000 µF capacitor at 5 V
E = ½ × C × V² = 0.5 × 0.001 × 25 = 12.5 mJ. That is enough to bridge a very short supply dip, not to run a load for seconds.
Charge time through a resistor
A 1 kΩ resistor with a 1000 µF capacitor gives τ = 1 s. The capacitor is about 63% charged after 1 second and nearly full after 5 seconds.
Inputs
- Capacitance — Unit: F
- Frequency — Unit: Hz
- Voltage — Unit: V
- Resistance — Unit: Ω
What the result means
- Capacitive reactance — Unit: Ω
- Stored energy — Unit: J
- RC time constant — Unit: s
Practical tips and common mistakes
- Place a 100 nF ceramic capacitor right at each IC's power pins, and add a larger 10–100 µF capacitor near the module for current surges such as ESP32 radio bursts.
- Choose a voltage rating comfortably above the working voltage; at least 1.5 to 2 times is a common rule.
- Electrolytic and tantalum capacitors are polarized. Connecting them backwards can make them fail violently.
- Real capacitors lose capacitance under DC bias (ceramic X5R and X7R types), age, and have ESR that limits high-frequency performance. Treat the calculated value as ideal.
Assumptions and limitations
- Use farads and hertz in the formulas.
- Real capacitors have tolerance, ESR, leakage, and voltage ratings.
- The RC time constant assumes a first-order circuit and a fixed resistance.
Frequently asked questions
What does 104 mean on a capacitor?
104 means 10 followed by four zeros picofarads: 100 000 pF, which is 100 nF or 0.1 µF. It is the standard decoupling capacitor value.
How long does a capacitor take to charge?
Through a resistor, it reaches 63 % of the supply voltage after one time constant (τ = R × C) and over 99 % after five. A 100 µF capacitor through 10 kΩ has τ = 1 s, so it is effectively charged after 5 s.
Can I use a capacitor with a higher voltage rating?
Yes. A higher voltage rating is always safe; it is only bigger and sometimes more expensive. Never use one rated below the circuit voltage.
What is capacitive reactance?
It is the opposition a capacitor offers to AC, measured in ohms: Xc = 1 ÷ (2π f C). A 100 nF capacitor is about 1.6 kΩ at 1 kHz but only 1.6 Ω at 1 MHz.
Learn more